Specifications Saluki S3601A Keysight E5063A-235
Frequency Range 100kHz – 3GHz 100kHz – 3GHz
Frequency Resolution 1 Hz 1 Hz
Frequency Accuracy ±5×10-6 (23°C±3°C) NA
Output Power -45 to +10dBm -20 to 0dBm
System Dynamic Range Frequency range IF=10Hz IF=3kHz Frequency range IF=10Hz IF=3kHz
100kHz – 1MHz 90 60 100kHz – 300kHz 88 63
1MHz – 10MHz 110 80 300kHz – 8.5MHz 93 68
10MHz – 3GHz 125 95 8.5MHz – 3GHz 117 92
Noise Floor 100kHz – 10MHz -90dBm 100kHz – 8.5MHz -103
10MHz – 3GHz -115dBm 8.5MHz – 3GHz -127
Harmonic < -18dBc NA
Effective Directionality 100kHz – 1MHz 49 100kHz – 1MHz 49
1MHz – 3GHz 46 1MHz – 3GHz 46
Effective Source Match 100kHz – 1MHz 44 100kHz – 1MHz 41
1MHz – 3GHz 40 1MHz – 3GHz 40
Effective Load Match 100kHz – 1MHz 49 100kHz – 1MHz 47
1MHz – 3GHz 46 1MHz – 3GHz 46
Reflection Tracking 100kHz – 1MHz ±0.03 100kHz – 1MHz ±0.011
1MHz – 3GHz ±0.02 1MHz – 3GHz ±0.021
Transmission Tracking 100kHz – 1MHz ±0.03 100kHz – 1MHz ±0.082
1MHz – 3GHz ±0.02 1MHz – 3GHz ±0.037
Magnitude Trace Noise

(Frequency=1GHz, IF=3kHz)

0.001 dB rms Magnitude Trace Noise

(Frequency=1GHz, IF=70kHz)

0.005 dB rms
Phase Trace Noise

(Frequency=1GHz, IF=3kHz)

0.01 dB rms Magnitude Trace Noise

(Frequency=1GHz, IF=70kHz)

0.009 dB rms
Analysis Domain Frequency/Time (standard) Frequency/Time (option)
IF Bandwidth 1Hz – 5MHz (stepping by 1,2,3,5,7) NA
Sweep Point 1 -16001 NA
Port Connector Type N type (Female), 50Ω impedance N type (Female), 50Ω impedance
Measurement of Ports 2 port (standard) 2 port (standard)
Peripheral Interface USB, GPIB, VGA, LAN USB, GPIB, VGA, LAN
Dimension (W*H*D) 435*233*348mm 432*235*277mm
Max. Power Consumption 150W 120W
Max. Weight 16kg 11kg

Related link: S3601B Product Comparion with Keysight E5071C.